Burners

SINGLE BURNERS JET

This is a high-speed burner type “mixing nozzle”, the oxidizer and fuel are mixed in the combustion head. Produce a tense flame that allows penetration of the heat in the combustion chamber.
Burners JET can be used both in cooking chambers with fiber insulation, which a refractory insulating material or dense low density.
They can be of two types, lateral burner or ceiling burner.
The ignition burner JET mainly by high voltage discharge electrode provided by a plug, can also be applied a system for igniting a pilot flame.
Flame detection is performed by a special electrode, but you can use the UV photoelectric cell. The flame detection systems are required on all burners operating at temperatures below 750 °C.

Burners JET can operate with different combustion regimes depending on the application: On-Off with power ratio equal to 1:20, the pulse using the valve to the gas metering and pneumatic control of the combustion air or modular valve with combustion air control is using a motorized valve and gas dosing with the valve.

Burners JET can also operate with the combustion air preheated to 400 ° C with the advantage of having a high flame temperature and thus lower fuel consumption, but with a slight elevation values NOx.

Download technical data sheet (.pdf)

BR-70JET-VG
Ceiling burner, gas fuel
BR-70JET-VG

BR-70JET-LG
Lateral inclusion, gas fuel
BR-70JET-LG

PARAMETER NATURAL GAS PROPANE BUTANE
Maximum Input (kW) 81,5 81,5 81,5
Rated Input (kW) 70,0 70,0 70,0
Minimum Input (kW) 17,0 17,0 17,0
Maximum Temperature (°C) 1000 1000 1000
Maximum Flame Velocity (m/s) 220
High Fire Flame Length (mm) 750 600 600

BR-70JET-LG-PLUS
Ceiling burner, gas fuel
BR-70JET-LG-PLUS

PARAMETER NATURAL GAS PROPANE BUTANE
Maximum Input (kW) 81,5 81,5 81,5
Rated Input (kW) 70,0 70,0 70,0
Minimum Input (kW) 17,0 17,0 17,0
Maximum Temperature (°C) 1200 1200 1200
Maximum Flame Velocity (m/s) 200
High Fire Flame Length (mm) 680 500 500

BR-95JET-VG
Ceiling burner, gas fuel, with controlled ignition
BR-95JET-VG

BR-95JET-LG
Lateral burner, gas fuel, with controlled ignition
BR-95JET-LG

PARAMETER NATURAL GAS PROPANE BUTANE
Maximum Input (kW) 100 100 100
Rated Input (kW) 95 95 95
Minimum Input (kW) 15 15 15
Maximum Temperature (°C) 1250 1250 1250
Maximum Flame Velocity (m/s) 220
High Fire Flame Length (mm) 860 780 780

BR-105JET-VG
Ceiling burner, gas fuel, with controlled ignition
BR-105JET-VG

BR-105JET-LG
Lateral burner, gas fuel, with controlled ignition
BR-105JET-LG

PARAMETER NATURAL GAS PROPANE BUTANE
Maximum Input (kW) 122 122 122
Rated Input (kW) 105 105 150
Minimum Input (kW) 15 15 15
Maximum Temperature (°C) 1100 1100 1100
Maximum Flame Velocity (m/s) 220
High Fire Flame Length (mm) 860 780 780

BR-220JET-LG
Lateral burner, gas fuel, with controlled ignition
BR-220JET-LG

PARAMETER NATURAL GAS PROPANE BUTANE
Maximum Input (kW) 255 255 255
Rated Input (kW) 220 220 220
Minimum Input (kW) 20 20 20
Maximum Temperature (°C) 1250 1250 1250
Maximum Flame Velocity (m/s) 200
High Fire Flame Length (mm) 910 800 800

BR-70JET-VO
Ceiling burner, oil fuel
BR-70JET-VO

PARAMETER LIGHT OIL HEAVY OIL DIESEL
Maximum Input (kW) 81.5 81.5 81.5
Rated Input (kW) 70.0 70.0 70.0
Minimum Input (kW) 17.0 17.0 17.0
Maximum Temperature (°C) 1000 1000 1000
Maximum Flame Velocity (m/s) 140
High Fire Flame Length (mm) 480 600 400

BR-100JET-VO
Ceiling burner, oil fuel
BR-100JET-VO

PARAMETER LIGHT OIL HEAVY OIL DIESEL
Maximum Input (kW) 120 120 120
Rated Input (kW) 100 100 100
Minimum Input (kW) 20 20 20
Maximum Temperature (°C) 1000 1000 1000
Maximum Flame Velocity (m/s) 180
High Fire Flame Length (mm) 520 680 480

BR-70JET-4 (RATIO 1-3/1-4)
Ceiling burner, oil fuel, mechanical pulverization
BR-70JET-4

PARAMETER LIGHT OIL HEAVY OIL DIESEL
Maximum Input (kW) 110 110 110
Rated Input (kW) 70.0 70.0 70.0
Minimum Input (kW) 17.0 17.0 17.0
Maximum Temperature (°C) 1000 1000 1000
Maximum Flame Velocity (m/s) 48 48 48
High Fire Flame Length (mm) 2800 2800 2800

BR-T8
Ceiling burner, oil fuel, with controlled ignition
BR-T8

PARAMETER LIGHT OIL HEAVY OIL DIESEL
Maximum Input (kW) 150 150 150
Rated Input (kW) 105 105 105
Minimum Input (kW) 25 25 205
Maximum Temperature (°C) 1000 1000 1000
Maximum Flame Velocity (m/s) 180
High Fire Flame Length (mm) 520 680 480

BR-LATERALE
Lateral burner, oil fuel, with controlled ignition
BR-LATERALE

PARAMETER LIGHT OIL HEAVY OIL DIESEL
Maximum Input (kW) 250 250 250
Rated Input (kW) 220 220 220
Minimum Input (kW) 25 25 25
Maximum Temperature (°C) 1000 1000 1000
Maximum Flame Velocity (m/s) 140
High Fire Flame Length (mm) 480 600 400

Multiple Burners

High speed burners used with all gaseous fuels.
Lateral installation with flame or no-flame control, to use in areas with lower or higher temperatures compared to the controlled ignition temperature of the fuel.
Flame control made with electrodes or photocells.

BR-F-JET-LG
Kiln Lateral Burner
Lateral burner, gas fuel, with controlled ignition
BR-F-JET-LG

PARAMETER VALUE
Maximum Input (kW) 765
Rated Input (kW) 660
Minimum Input (kW) 60
Maximum Temperature (°C) 1250
Fuel Natural Gas, Propane, Butane

BR-F-JET-VG-CA
Kiln Ceiling Burner
Ceiling burner, gas fuel, with controlled ignition
BR-F-JET-VG-CA

PARAMETER VALUE
Maximum Input (kW) 1050
Rated Input (kW) 950
Minimum Input (kW) 170
Maximum Temperature (°C) 1000
Fuel Natural Gas, Propane, Butane

BR-F-JET-VG-AA
Kiln Ceiling Burner
Ceiling burner, gas fuel
BR-F-JET-VG-AA

PARAMETER VALUE
Maximum Input (kW) 800
Rated Input (kW) 700
Minimum Input (kW) 170
Maximum Temperature (°C) 1000
Fuel Natural Gas, Propane, Butane

BR-LATERALE
Kiln Lateral Burner
Lateral burner, oil fuel, with auto-ignition
BR-LATERALI-MULTIPLI

PARAMETER VALUE
Maximum Input (kW) 1400
Rated Input (kW) 1000
Minimum Input (kW) 170
Maximum Temperature (°C) 1000
Fuel Heavy oil, Light oil, Diesel

BR-F-JET-VO-AA-PLUS
Kiln Ceiling Burner
Ceiling burner, oil fuel, auto-ignition
BR-F-JET-VO-AA-PLUS

PARAMETER VALUE
Maximum Input (kW) 2100
Rated Input (kW) 1400
Minimum Input (kW) 340
Maximum Temperature (°C) 1000
Fuel Heavy oil, Light oil, Diesel

BR-E-JET-VO-AA
Kiln Ceiling Burner
Ceiling burner, oil fuel, with continuous pulses
BR-E-JET-VO-AA

PARAMETER VALUE
Maximum Input (kW) 1630
Rated Input (kW) 1400
Minimum Input (kW) 340
Maximum Temperature (°C) 1000
Fuel Heavy oil, Light oil, Diesel

BR-F-JET-4 (RATIO 1-3/1-4)
Kiln Ceiling Burner
Ceiling burner, oil fuel, with pulses
BR-F-JET-4

PARAMETER VALUE
Maximum Input (kW) 1100
Rated Input (kW) 700
Minimum Input (kW) 170
Maximum Temperature (°C) 1000
Fuel Heavy oil, Light oil, Diesel

BR-S.F.B.
Ceiling burner, solid fuels
BR-E-JET-VO-AA

PARAMETER COAL (COOK) SAWDUST (WOOD) POMACE OIL (OLIVES)
Maximum Input (kW) 1100 1100 1100
Rated Input (kW) 770 770 770
Minimum Input (kW) 170 170 170
Maximum Temperature (°C) 1000 1000 1000

BURNERS – Grinding System

Grinding, storage and distribution plant of solid fuels
Different kind of burners for solid fuel kilns:

  • Fuel grinding and distribution system
  • Electronically dosage control system
  • Auto-ignition burners for combustion zone
  • Heads burners specifically designed to optimize combustion
  • Compatible with charcoal and fuels of vegetable origin (biomass)
  • Different powers available for all ceramic industry applications

Scarica la scheda tecnica (.pdf)

GRINDING SYSTEM

CASE HISTORIES

Pratigliolmi – Cotto Nobile di Toscana (Italy)

Easymud® line

Read More
Maestrale S.r.l. (Italy)

Robotized plant for the production of 40 million roof tiles/year

Read More
Flemings Fireclay Manufacturing (Ireland)

Complete robotized plant for flue liners

Read More

NEWSLETTER

Subscribe now!

Subscribe

IN THE WORLD

WORK WITH US

Send now your CV...

Read More
Back to top